Repurposing Low-Cost Consumer Technology for Motion Correction in Dementia Neuroimaging

Award Number
MR/M025004/1
Programme
Research Grant
Status / Stage
Active
Dates
1 July 2015 -
31 December 2016
Duration (calculated)
01 years 05 months
Funder(s)
MRC (UKRI)
Funding Amount
£204,400.49
Funder/Grant study page
MRC UKRI
Contracted Centre
Imperial College London
Contracted Centre Webpage
Principal Investigator
Professor Gunn, Roger
PI Contact
r.gunn@imperial.ac.uk
PI ORCID
0000-0003-1181-5769
WHO Catergories
Development of novel therapies
Economic Impact of Dementia
Disease Type
Dementia (Unspecified)

CPEC Review Info
Reference ID#REF!
ResearcherReside Team
Published12/06/2023

Data

Award NumberMR/M025004/1
Status / StageActive
Start Date20150701
End Date20161231
Duration (calculated) 01 years 05 months
Funder/Grant study pageMRC UKRI
Contracted CentreImperial College London
Contracted Centre Webpage
Funding Amount£204,400.49

Abstract

Subject motion has long been recognised as a limiting factor in many medical imaging procedures, and remains an unsolved problem, producing inaccurate data that impacts on costs and effective diagnosis/treatment. This is particularly so for the latest generation of scanners whose intrinsic resolution exceeds the ability of patients to remain still, for example in neurodegenerative disorders. Algorithms to correct for motion are well established, yet the lack of effective, affordable, reliable motion tracking hardware has prevented widespread adoption in both research and clinical settings. Currently, there are no commercially available solutions and motion correction is limited to post-processing of scan data with its inherent limitations. PET is a well-established neuroimaging research tool, becoming ever more important for dementia in the clinic and in drug development with novel tracers for amyloid and tau offering unique biochemical information. For these patient populations motion is a significant problem. In a recent EPSRC/GSK CASE PhD, we acquired promising pilot data by repurposing a low cost mass-market consumer technology (Microsoft Kinect), coupling it with machine vision techniques to accurately measure PET head motion in real time with sub-mm accuracy providing confidence it could be developed into an effective device for the clinical environment. This is all achieved without special lighting, subject contact or attachment of markers that have compromised previous efforts. We have recently obtained evidence that this hardware will also work within an MRI scanning environment. More work is required to optimise, evaluate and commercialise our applications. We will work with Imanova, with access to key expertise, to develop the technology for PET and PET/MR research imaging in neurodegeneration where it will provide an immediate impact in particular for the new MRC Dementia Platform (http://dementiasplatform.uk).

Aims

We will work with Imanova, with access to key expertise, to develop the technology for PET and PET/MR research imaging in neurodegeneration where it will provide an immediate impact in particular for the new MRC Dementia Platform